ERTL & SAMEER Tested
UPS (Online UPS & Line Interactive), Lift UPS, Stabilizer, Inverter (Sinewave & Quasi), Batteries (SMF & Tubular), CVT, Battery Charger, UPS on Rent.
Products
 


Technical Specifications
INPUT REQUIREMENTS           
          Voltage

          Frequency
        :  230 VAC (+20% to 30%) for Single Phase
        :  400 VAC (+15% to 30%) for Three Phase
        :  50 Hz (±6%)
OUTPUT PERFORMANCE
          Voltage Regulation

          Frequency Stability
          Wave Form
          Total Harmonic
          distortion
          Over Load Handling

          Power Factor
        : 230 VAC ±1% for single phase
        : 400 VAC ±1% for three phase
        : 50 Hz ± 0.01% (Crystal Controlled)
        : True Sine Wave
        : <2% on Linear Load
        : <4% on Non Linear Load
        : 120% for 10 Min.
        : 150% for 60 Sec.
        : 0.8 pl  
BATTERY DETAILS          
          Battery Voltage (VDC)
          Rectifier Type
          Charge Type
        : 48, 72, 96, 120, 144, 192, 240, 300, 360, 384V
        : Full bridge half control
        : Solid State with Float & Boost Charging facility     
SPECIAL FEATURE          
          Transient Response


          Efficiency

          Crest Factor
          Accoustic Noise
        : For 0 to 100% step load change in the output
          will remain within+- 5% & recover upto 98%
          within 10 msec.
        : DC to AC (Inverter) > 90%
          AC to AC (Overall) > 80%
        : 3:1
        : <50 dBA at a distance of 1 meter.
METERING (DIGITAL DISPLAY)          
          DC Voltage
          Output Voltage
          Input Voltage (Optional)
          Output Current (Optional)
          Output Frequency (Optional)
          Battery Current (Optional)
          
PROTECTIONS          
          Input MCB
          Battery MCB
          Output Fuse
          Mains Under / Over Voltage
          Battery charging current limit
          Battery Under Voltage
          Output overload
          Output Short circuit
          Output Under / Over Voltage
          
INDICATIONS (LED’s for)          
          Mains on
          Inverter on
          Load on Mains
          Load on UPS
          Mains fail
          Batt. Low
          Trip
          
ALARM          
          All Fault Conditions.           
UPS DIMENSIONS          
 Capacity         Phase        H        L       W
01-7.5kVA      1Ph-1Ph    530    640    290
1Ph-1Ph         3Ph-1Ph    650    650    320
3Ph-1Ph        10-12kVA   710    770    320
10-15kVA      20-25kVA   750    750    450

  Capacity         Phase        H            L            W
30-40kVA        3Ph-3Ph     850      1100       450
50-60kVA        3Ph-3Ph     850      1200       450
80-100kVA      3Ph-3Ph     1300     950        960

Back

  Prompt is committed to provide round   the clock support to its esteemed   Customers.