ERTL & SAMEER Tested |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
 |
Products |
 |
 |
| |
 |
 |
|
 |
|
|
| |
PUS 500L |
PUS 1000L |
PUS 2000L |
| Capacity VA/W |
500VA/300W |
1000VA/600W |
2000VA/1200W |
| Input |
| Voltage Range |
140-300VAC |
| Frequency Range |
50 or 60HZ (Auto Detect) |
| Output |
| Voltage |
220V AC +12% to -18% |
| Frequency |
50 or 60HZ +/-0.1HZ |
| Waveform |
Modified Sinewave |
| Transfer Time |
4-8mS typical, 14mS max |
| Battery |
| Type |
Lead-acid or maintenance Free |
| Voltage |
12V |
12V |
24V |
| Charging Current |
10A |
| Batt. Capacity |
50Ah to 100AH |
| Backup Time |
(Refer Backup Time Chart below) |
| On 190Ah Full Load |
3h40m |
| Indicators |
| Mains Mode |
Green Lighting |
| Battery Mode |
Yellow Lighting |
| Charging Mode |
Green Flashing |
| Over Load |
Red Flashing every half second |
| Fault |
Red lighting |
| Audible Alarm |
| Battery mode |
Sounds every 10 seconds |
| Low Battery |
Sounds every 2 second |
| Overload |
Sounds every 0.5 seconds |
| Fault |
Sounds continuously |
| Protection |
Discharge, overcharge, and overload protection |
| Physical |
| Dimensions (WxDxH mm) |
402X117X222 |
| Net Weight (kgs) |
1.7 |
4.9 |
6.5 |
Back |
 |
|
 |
 |
 |
 |
 |